What size dehumidifier do I need?
Pints per day on today's rating, with the common size to buy in brackets, by floor area and how damp the space is without a dehumidifier. Portable units are sold most often in 22, 25, 35, 50 pint sizes; past 50 pints, look at a whole-home unit (about 65 pints and up) or two portables.
| Floor area | Moderately damp | Very damp | Wet | Extremely wet |
|---|---|---|---|---|
| 300 sq ft | 20 (22 pint) | 25 (25 pint) | 30 (35 pint) | 35 (35 pint) |
| 500 sq ft | 20 (22 pint) | 25 (25 pint) | 30 (35 pint) | 35 (35 pint) |
| 700 sq ft | 22 (22 pint) | 27 (35 pint) | 33 (35 pint) | 38 (50 pint) |
| 1,000 sq ft | 24 (25 pint) | 30 (35 pint) | 37 (50 pint) | 43 (50 pint) |
| 1,200 sq ft | 25 (25 pint) | 32 (35 pint) | 40 (50 pint) | 46 (50 pint) |
| 1,500 sq ft | 27 (35 pint) | 35 (35 pint) | 44 (50 pint) | 50 (50 pint) |
| 2,000 sq ft | 30 (35 pint) | 40 (50 pint) | 50 (50 pint) | 58 (whole-home) |
| 2,500 sq ft | 36 (50 pint) | 48 (50 pint) | 60 (whole-home) | 69 (whole-home) |
| 3,000 sq ft | 41 (50 pint) | 55 (whole-home) | 69 (whole-home) | 80 (whole-home) |
- Moderately damp: Feels damp and smells musty now and then. About 50 to 75% relative humidity.
- Very damp: Always feels and smells damp; damp spots on walls or floor. About 75 to 90%.
- Wet: Walls or floor sweat, or water seeps in. About 90 to 100%.
- Extremely wet: Wet floor, laundry drying, very high moisture load.
ENERGY STAR sets the levels: moderately damp 20 to 30 pints under 2,000 sq ft and 30 or more above; very damp 25 to 40 pints under 2,000 sq ft and 40 or more above; wet 30 to 50 pints under 2,000 sq ft and 50 or more above. Where a space falls inside that range by size, and the extremely wet column, follow the shape of the AHAM chart; that scaling is ours.
What size dehumidifier for a basement?
A 1,500 sq ft basement needs about 27 pints per day if it is moderately damp and 35 if it always feels damp, so a 35 or 35 pint unit. Basements are where today's rating was set: DOE moved the test from 80°F to 65°F to match them. Below about 65°F, frost can form on the coils, so in a cold basement pick a model rated for low temperatures. Run a hose to a floor drain or sump, or buy a model with a pump, so you are not emptying a bucket every day.
Old vs new pint ratings: why dehumidifiers seem smaller now
Since June 2019, portable dehumidifiers have been tested at 65°F instead of 80°F. Cooler air holds less water, so the same machine now earns a smaller number. ENERGY STAR's rough conversion:
| Portable, before 2019 | Portable, today | Whole-home, before 2019 | Whole-home, today |
|---|---|---|---|
| 30 pints | 20 pints | 80 pints | 70 pints |
| 40 pints | 25 pints | 100 pints | 85 pints |
| 50 pints | 30 pints | 120 pints | 100 pints |
| 55 pints | 32.5 pints | 140 pints | 115 pints |
| 60 pints | 35 pints | 160 pints | 135 pints |
| 70 pints | 42.5 pints | 200 pints | 170 pints |
| 90 pints | 55 pints |
Where ENERGY STAR gives a range (55 old pints became 30 to 35, 70 became 40 to 45) the table shows the middle. Makers' relabels do not always agree: TCL, for one, lists its old 70 pint models as today's 50 pint.
Older advice uses the AHAM chart, which is in old pints and asks for less than ENERGY STAR's current guide even after converting: for a very damp 1,000 sq ft space it said 17 pints, about 11 on today's scale, where ENERGY STAR now says 25 to 40. ENERGY STAR also says it is better to oversize than to undersize, so this calculator follows the current guide.
| AHAM chart, old pints | 500 sq ft | 1,000 sq ft | 1,500 sq ft | 2,000 sq ft | 2,500 sq ft |
|---|---|---|---|---|---|
| Moderately damp | 10 | 14 | 18 | 22 | 26 |
| Very damp | 12 | 17 | 22 | 27 | 32 |
| Wet | 14 | 20 | 26 | 32 | 38 |
| Extremely wet | 16 | 23 | 30 | 37 | 44 |
What size dehumidifier for a crawl space?
Use the same pints for the crawl space floor area, and buy a unit built for crawl spaces: low-temperature rated, with a drain line or condensate pump. In the building code a dehumidifier is one of the options for a sealed (unvented) crawl space with a vapor barrier on the ground: IRC R408.3 lets it be sized to the maker's specifications. Many jurisdictions add their own rules, so check with your building department.
What humidity should a house be?
The EPA says to keep indoor humidity below 60%, ideally between 30 and 50%, to keep mold from growing. Set the dehumidifier's humidistat in that range and check it with an inexpensive humidity meter. If you are replacing an old unit, ENERGY STAR suggests judging the size by how much water you empty each day.
How the calculator works
- Pick the condition. ENERGY STAR gives a range for spaces under 2,000 sq ft and a minimum above.
- Up to 500 sq ft, the calculator uses the low end of the range. From 500 to 2,000 sq ft it climbs in a straight line to the high end, the way the AHAM chart grows with area.
- Above 2,000 sq ft it grows in proportion to the AHAM chart. Extremely wet is the wet figure times AHAM's extremely-wet to wet ratio.
- It rounds up to the next common size (22, 25, 35, 50 pints) and converts to the old rating with ENERGY STAR's table.
Sources
Sizing chart, condition descriptions and the 65°F frost note: ENERGY STAR, Dehumidifiers. The 2019 test change and old-to-new table: ENERGY STAR, Dehumidifier Testing and Capacity. AHAM chart (old rating), as ENERGY STAR published it until 2019: ENERGY STAR Dehumidifier Basics, archived 2017. Common sizes: ENERGY STAR certified dehumidifiers list (576 models, November 2026). A maker's relabel: TCL, Dehumidifier Testing Standards and Product Pint Capacity. Indoor humidity: EPA, A Brief Guide to Mold, Moisture, and Your Home. Crawl space code summary (IRC R408.3): Larimer County, Colorado, crawl space handout.
Related calculators
AC size calculator
BTUs and tons of cooling for your square footage and climate.
Furnace and heat pump size calculator
Heating BTUs for your home and winter lows, for a furnace or heat pump.
Water heater size calculator
Tank gallons or tankless flow for your household.
All heating and cooling calculators · More on heating and cooling