What size furnace do I need?
Furnace input size (BTU per hour) for a 1970s to 2000s house at 95% AFUE, rounded up to the common size whose output covers the load. Design temperatures are ASHRAE's 99% figures for each city.
| House size | Houston (34°F) | Atlanta (26°F) | Washington (21°F) | Chicago (3°F) | Minneapolis (-6°F) |
|---|---|---|---|---|---|
| 1,000 sq ft | 40,000 | 40,000 | 40,000 | 40,000 | 40,000 |
| 1,200 sq ft | 40,000 | 40,000 | 40,000 | 40,000 | 60,000 |
| 1,500 sq ft | 40,000 | 40,000 | 40,000 | 60,000 | 60,000 |
| 1,800 sq ft | 40,000 | 40,000 | 60,000 | 60,000 | 80,000 |
| 2,000 sq ft | 40,000 | 60,000 | 60,000 | 80,000 | 80,000 |
| 2,200 sq ft | 40,000 | 60,000 | 60,000 | 80,000 | 80,000 |
| 2,500 sq ft | 60,000 | 60,000 | 60,000 | 80,000 | 100,000 |
| 3,000 sq ft | 60,000 | 80,000 | 80,000 | 100,000 | 120,000 |
| 3,500 sq ft | 60,000 | 80,000 | 100,000 | 120,000 | 140,000 |
| 4,000 sq ft | 80,000 | 100,000 | 100,000 | 140,000 | Over 140,000 |
Where even the smallest common size, 40,000 BTU input, puts out more than 140% of the load (warm cities, small houses), Manual S would call it oversized; look at a smaller or two-stage furnace, or a heat pump. A newer house needs about 33% less than these figures; an older, drafty one about 44% more.
How many BTU does it take to heat a house?
Heating load in BTU per hour on a design-cold day in Chicago (3°F outside, 70°F inside), by how well the house holds heat.
| House size | Newer, built to code since about 2010 | 1970s to 2000s house | Older or drafty, little wall insulation |
|---|---|---|---|
| 1,000 sq ft | 20,000 | 30,000 | 43,400 |
| 1,500 sq ft | 30,000 | 45,000 | 65,000 |
| 2,000 sq ft | 40,000 | 60,000 | 86,700 |
| 2,500 sq ft | 50,000 | 75,000 | 108,400 |
| 3,000 sq ft | 60,000 | 90,000 | 130,100 |
The load scales with the gap between inside and outside. Atlanta's design temperature is 26°F, a 44°F gap against Chicago's 67°F, so the same house there needs about 65% of these figures. A furnace size copied from a house in another climate can be far off.
What size heat pump do I need?
Tons of cold-climate heat pump for a 1970s to 2000s house. Where even a 5 ton unit (the largest home size) falls short at the design temperature, the table adds the electric backup heat in kW that covers the rest.
| House size | Atlanta (26°F) | Washington (21°F) | Chicago (3°F) | Minneapolis (-6°F) |
|---|---|---|---|---|
| 1,000 sq ft | 2 tons | 2.5 tons | 4 tons | 5 tons |
| 1,200 sq ft | 2.5 tons | 3 tons | 5 tons | 5 tons + 1.1 kW |
| 1,500 sq ft | 3 tons | 3.5 tons | 5 tons + 1.1 kW | 5 tons + 4.1 kW |
| 1,800 sq ft | 3.5 tons | 5 tons | 5 tons + 3.7 kW | 5 tons + 7.1 kW |
| 2,000 sq ft | 4 tons | 5 tons | 5 tons + 5.5 kW | 5 tons + 9.1 kW |
| 2,200 sq ft | 5 tons | 5 tons | 5 tons + 7.3 kW | 5 tons + 11.1 kW |
| 2,500 sq ft | 5 tons | 5 tons + 2.0 kW | 5 tons + 9.9 kW | 5 tons + 14.1 kW |
| 3,000 sq ft | 5 tons + 2.3 kW | 5 tons + 5.2 kW | 5 tons + 14.3 kW | 5 tons + 19.1 kW |
| 3,500 sq ft | 5 tons + 5.1 kW | 5 tons + 8.5 kW | 5 tons + 18.7 kW | 5 tons + 24.2 kW |
| 4,000 sq ft | 5 tons + 8.0 kW | 5 tons + 11.7 kW | 5 tons + 23.1 kW | 5 tons + 29.2 kW |
A heat pump's rating is its output at 47°F, and it loses capacity as the air gets colder. On ENERGY STAR's list of certified models, standard heat pumps keep a median 65% of their rated heat at 17°F. To earn ENERGY STAR's cold-climate label, a model must keep at least 70% at 5°F, and half of the certified cold-climate models keep 78% or more. The calculator uses the 70% floor, so a strong cold-climate model may need a size smaller than shown; check its capacity table at your design temperature (NEEP's cold-climate heat pump list publishes these).
Two numbers decide the backup heat. The balance point is the outdoor temperature where the heat pump's output equals the house's heat loss; below it, electric strips (or a furnace in a dual-fuel setup) make up the difference. DOE draws the house's load as a straight line from the design load down to zero at 65°F. The shortfall at the design temperature, divided by 3,412 BTU per kW, is the backup heat to install. For the default house above, a 5 ton cold-climate unit covers the house down to about 17°F and needs 5.5 kW of strips at 3°F.
What is the design temperature for my city?
The 99% heating design temperature is the outdoor temperature that is colder only 1% of the hours in a typical year (about 88 hours). Load calculations size heating for that temperature, not for the record low. These are ASHRAE's figures, from 1994 to 2019 weather data.
| City | Weather station | 99% design temperature |
|---|---|---|
| Miami, FL | Miami NHC | 53°F |
| Los Angeles, CA | Los Angeles Intl | 47°F |
| Phoenix, AZ | Phoenix Sky Harbor | 42°F |
| Las Vegas, NV | Las Vegas McCarran | 35°F |
| Houston, TX | Houston Bush | 34°F |
| Seattle, WA | Seattle Tacoma | 30°F |
| Dallas, TX | Dallas Fort Worth | 27°F |
| Atlanta, GA | Atlanta Hartsfield-Jackson | 26°F |
| Charlotte, NC | Charlotte Douglas | 25°F |
| Washington, DC | Washington Reagan | 21°F |
| Nashville, TN | Nashville Intl | 20°F |
| New York, NY | New York LaGuardia | 18°F |
| Philadelphia, PA | Philadelphia Intl | 18°F |
| Salt Lake City, UT | Salt Lake City Intl | 16°F |
| Boston, MA | Boston Logan | 13°F |
| St. Louis, MO | St Louis Lambert | 12°F |
| Columbus, OH | Columbus Glenn | 10°F |
| Detroit, MI | Detroit Wayne County | 7°F |
| Kansas City, MO | Kansas City Intl | 7°F |
| Denver, CO | Denver Intl | 6°F |
| Chicago, IL | Chicago O'Hare | 3°F |
| Milwaukee, WI | Milwaukee Mitchell | 3°F |
| Burlington, VT | Burlington Intl | -2°F |
| Anchorage, AK | Anchorage Intl | -3°F |
| Minneapolis, MN | Minneapolis-St Paul | -6°F |
| Fargo, ND | Fargo Hector | -14°F |
| Fairbanks, AK | Fairbanks | -38°F |
Your local building department may set its own design temperature for permits; if it does, use that one in the custom field.
What does AFUE mean?
AFUE (annual fuel utilization efficiency) is the share of the fuel's heat that reaches the house over a season. Furnaces are sold by their input rating, so the heat you get is input x AFUE.
| AFUE | Heat from 100,000 BTU of gas | Input for a 60,000 BTU/h load |
|---|---|---|
| 80% (standard) | 80,000 BTU | 75,000 BTU/h |
| 95% (ENERGY STAR, South) | 95,000 BTU | 63,158 BTU/h |
| 97% (ENERGY STAR, North) | 97,000 BTU | 61,856 BTU/h |
80% is the federal minimum for most indoor gas furnaces made until December 18, 2028, when it rises to 95%. ENERGY STAR certifies gas furnaces at 95% AFUE or more in southern states and 97% or more in northern ones.
How the calculator works
- Temperature gap: 70°F inside minus your city's 99% design temperature (the outdoor temperature that is colder only 1% of the hours in a year).
- Heating load = heated floor area x heat-loss factor x temperature gap. The factors, in BTU per hour per sq ft per °F, are 0.30 for a newer house, 0.45 for a 1970s to 2000s house and 0.65 for an older, drafty one.
- Furnace: input rating = load / AFUE, rounded up to a common size (40,000, 60,000, 80,000, 100,000, 120,000, 140,000 BTU).
- Heat pump: tons = load / (12,000 x the share of rated heat it keeps at the design temperature), rounded up to a size from 1.5 to 5 tons. Any shortfall / 3,412 = backup kW.
The heat-loss factors are our estimates, not a published table. The newer-house figure matches DOE Building America's Manual J examples for houses built to the 2009 energy code (about 0.28 in Chicago and 0.33 in Orlando). The 1970s to 2000s figure is worked out from ENERGY STAR's typical-house assumptions for homes of that era: R-11 walls, an R-15 attic, double-pane windows and leaky air sealing come to about 0.43, plus duct losses. Use the custom factor if you have a better number, for example from an energy audit.
When do you need a Manual J load calculation?
Before you buy. ACCA's Manual J adds up each wall, window, ceiling and floor, the air leakage and the ducts, which a square-foot estimate cannot. DOE's Building America guide, following ACCA's Manual S, keeps a furnace's output within 140% of the calculated load. A heat pump in a cold climate may be sized above the cooling load to cover more of the heat, as long as the contractor picks a unit that can turn down for summer.
Sources
Design temperatures: ASHRAE Handbook of Fundamentals 2021 climatic design conditions, via ashrae-meteo.info. Example loads, the balance-point method and Manual S limits: DOE Building America, Strategy Guideline: HVAC Equipment Sizing (Burdick, 2012). Typical 1970s to 1980s house: ENERGY STAR, Seal and Insulate Savings Analysis Baseline Home Assumptions. Federal AFUE minimums: 10 CFR 430.32(e). ENERGY STAR furnace levels: ENERGY STAR Furnaces Key Product Criteria; common input sizes from the ENERGY STAR certified furnaces list. Cold-climate criteria: ENERGY STAR Heat Pump Key Product Criteria; capacity at 17°F and 5°F from the ENERGY STAR certified air-source heat pumps list (284,747 combinations, November 2026); straight-line capacity between test points as in DOE guidance on heat pump performance at 5°F. Sizing approaches for cold climates: PNNL Building America Solution Center, Cold Climate Heat Pump Sizing and Selection. kW to BTU: EIA, British thermal units.